Where should the station's lightning protection ground system be located?

  1. AAs close to the station equipment as possible
  2. BOutside the building
  3. CNext to the closest power pole
  4. DParallel to the water supply line
Why Lightning protection works by giving surge current a short, direct path to earth before it can enter the building. Coax shields, rotator and control lines should pass through surge arrestors mounted on a ground panel or entry plate outside the structure, bonded to ground rods driven into the earth there. That ground system must also be bonded back to the AC service entrance ground so everything rises and falls in potential together, which is what prevents damaging differences between grounds.
Watch out Putting the lightning ground right at the operating position sounds convenient but it drags the surge current through the building and through your equipment on its way to earth, which is exactly what you are trying to avoid.
Stop the strike at the door: arrestors and ground rods go outside, bonded to the service ground.
HamSandwich explanation, first draft. The question and answers are the NCVEC text.
← G0B03 All of G0B G0B05 →

The rest of G0B

  1. G0B01 Which wire or wires in a four-conductor 240 VAC circuit should be attached to fuses or circuit breakers?
  2. G0B02 According to the National Electrical Code, what is the minimum wire size that may be used safely for wiring w…
  3. G0B03 Which size of fuse or circuit breaker would be appropriate to use with a circuit that uses AWG number 14 wiri…
  4. G0B04 Where should the station's lightning protection ground system be located?
  5. G0B05 Which of the following conditions will cause a ground fault circuit interrupter (GFCI) to disconnect AC power?
  6. G0B06 Which of the following is covered by the National Electrical Code?
  7. G0B07 Which of these choices should be observed when climbing a tower using a safety harness?
  8. G0B08 What should be done before climbing a tower that supports electrically powered devices?
  9. G0B09 Which of the following is true of an emergency generator installation?
  10. G0B10 Which of the following is a danger from lead-tin solder?
  11. G0B11 Which of the following is required for lightning protection ground rods?
  12. G0B12 What is the purpose of a power supply interlock?
  13. G0B13 Where should lightning arrestors be located?