Study › Technician › T0A › T0A06

T0A06

SAFETY · Power circuits and hazards: hazardous voltages, fuses and circuit breakers, grounding, electrical code compliance; Lightning protection; Battery safety

T0A06T0A →

What is a good way to guard against electrical shock at your station?

  1. AUse three-wire cords and plugs for all AC powered equipment
  2. BConnect all AC powered station equipment to a common safety ground
  3. CEnsure all capacitors used for high-voltage DC are fully discharged before working inside equipment
  4. DAll these choices are correct
Why Shock protection at a station is layered, and all three practices listed do real work. Three-wire grounded cords and plugs give equipment chassis a low-resistance path back to the service ground so a fault trips the breaker instead of energizing the case. Bonding all gear to a single common safety ground prevents dangerous voltage differences between chassis that you might bridge with your body. And high-voltage filter capacitors can hold a lethal charge long after power is removed, so they must be bled down and verified discharged before you reach inside.
HamSandwich explanation, first draft. The question and answers are the NCVEC text.
← T0A05 All of T0A T0A07 →

The rest of T0A

  1. T0A01 Which of the following is a safety hazard of a 12-volt storage battery that lacks internal protection circuit…
  2. T0A02 What health hazard is posed by electrical current flowing through the body?
  3. T0A03 In the United States, what circuit does black wire insulation indicate in a three-wire 120 V AC cable?
  4. T0A04 What is the purpose of a fuse in an electrical circuit?
  5. T0A05 Why should a 5-ampere fuse never be replaced with a 20-ampere fuse?
  6. T0A06 What is a good way to guard against electrical shock at your station?
  7. T0A07 Where should a lightning arrester be installed in a coaxial feed line?
  8. T0A08 Where should a fuse or circuit breaker be installed in a 120V AC power circuit?
  9. T0A09 What should be done to all external ground rods or earth connections?
  10. T0A10 What hazard exists when rapidly charging or discharging an unprotected battery?
  11. T0A11 What hazard exists in a power supply immediately after turning it off?
  12. T0A12 Which of the following precautions should be taken when measuring high voltages with a voltmeter?
RG-213 Coax Cable 75ft with PL259 ConnectorsSponsored · View on Amazon →Baofeng BF-F8HP Pro Dual Band HandheldSponsored · View on Amazon →